Customization: | Available |
---|---|
Usage: | PLC MODULE |
Type: | New and original |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SLC 500 PLC MODULE 1746SC-IN04VI 1746SC-INI4VI 1746-HSCE 1746-IN16 1746-IM8 1746-P5 1746-OB8 1746-IN010 1746-UM005 1746-BASn 1746-KEn Input Module
SLC™ 500 4-Channel Thermocouple/mV Input Module
The thermocouple/mV module receives and stores digitally converted thermocouple and/or millivolt (mV) analog data into its image table for retrieval by all fixed and modular SLC 500 processors. The module supports connections from any combination of up to four thermocouple or mV analog sensors. The following tables define thermocouple types and their associated full scale temperature ranges and also list the millivolt analog input signal ranges that each 1746-NT4 channel will support. To determine the practical temperature range your thermocouple supports, refer to the specifications in Appendix A.
The thermocouple module fits into any single-slot, except the processor slot (0), in either an SLC 500 modular system or an SLC 500 fixed system expansion chassis (1746-A2). It is a Class 1 module (uses 8 input words and 8 output words). It interfaces to thermocouple types J, K, T, E, R, S, B, and N, and supports direct ±50 mV and ±100 mV analog input signals.
The module requires the use of Block Transfer in a remote configuration.
The module contains a removable terminal block providing connection for four thermocouple and/or analog input devices. There are also two, cold-junction compensation (CJC) sensors used to compensate for offset voltages introduced into the input signal as a result of the cold-junction, i.e., where the thermocouple wires connect to the module wiring terminal. There are no output channels on the module. Module configuration is done via the user program. There are no DIP switches.
The SLC 500 Digital Input Module 1746-IM8 comes with 8 channels. This module has voltage category of 200/240 Volts AC. It operates in temperatures between -25 and 60 degrees Celsius (-13 to 140 degrees Fahrenheit), and its non-operating temperatures range from -40 to 85 degrees Celsius (-40 to 185 degrees Fahrenheit). The relative humidity of this unit lies between 5% and 95% without condensation. It's operating vibration is approximately 1.0 g at 5 to 2000 Hertz; it has a total heat dissipation of 3.1 Watt, with 0.35 Watts per point and a 30 g operating shock.
The 1746-IM8 has an operating range of 170 to 265 Volts AC at 47 to 63 Hertz. The backplane current at 5 Volts of this module is 50 mA, while the same current at 24 Volts is 0 mA. The 1746-IM8 is supplied as open type equipment, intended for use in industrial environments no more than Pollution 2 (as defined in EN / IEC0664-1) when applied in a Zone 2 environment. The enclosure should be accessible only by means of the appliance. Keep equipment connected at all times until power is cut and the area is secured.
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for 1746-IM8
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
AB | 1746-NOI4I | AB | 1746-FIO4V | AB | 1492-IFM20F | AB | 1336-T-SP5A |
AB | 1746-NIO4V | AB | 1746-BTM | AB | 1440-VST02-01RA | AB | 1326AB-B430E-21 |
AB | 1746-IV32 | AB | 1745-LP102 | AB | 1440-VST02-01RA | AB | 1305-KBA09 |
AB | 1746-ITV16 | AB | 1745-E102 | AB | 1440-VSE02-01RA | AB | 1305-BA09A-HA2 |
AB | 1746-ITB16 | AB | 1738-IB16DM12 | AB | 1440-VLF02-01RA | AB | 1305-BA03A |
AB | 1746-IO8 | AB | 1734-VHSC24 | AB | 1440-TPS02-01RB | AB | 1305-BA01A-HA2 |
AB | 1746-IO12DC | AB | 1734-OE2CK | AB | 1440-TB-E | AB | 1336F-BRF100-AE-EN |
AB | 1746-IO12 | AB | 1734-OE2C | AB | 1440-TB-B | AB | 1336F-BRF100-AA-EN |
AB | 1746-INT4 | AB | 1734-OB8S | AB | 1440-TB-A | AB | 1336F-B025-AA-EN |
AB | 1746-IN16 | AB | 1732DS-IB8 | AB | 1398-DDM-009 | AB | 1336F-B015-AA-EN |
AB | 1746-IM8 | AB | 1606-XLS120E | AB | 1398-DDM-005-DN | AB | 1336-C003-EOD |
AB | 1746-IH16 | AB | 1606-XLP100E | AB | 1398-DDM-005 | AB | 1336-BDB-SP6A |
AB | 1746-IC16 | AB | 1606-XLE240EE | AB | 1395-A65N-C1-PZ | AB | 1336-BDB-SP5D |
AB | 1746-IB32 | AB | 1606-XLE240E | AB | 1394-SR9A | AB | 1336-BDB-SP5C |
AB | 1746-IA16 | AB | 1606-XLE120E | AB | 1394C-SJT10-T-RL | AB | 1336F-BRF20-AA-EN |
AB | 1746-HT | AB | 1606-XL60D | AB | 1394C-AM75-IH | AB | 1336F-BRF200-AA-EN |
AB | 1746-HSRV | AB | 1606-XL480EP | AB | 1394C-AM07 | AB | 1336F-BRF10-AA-EN |
AB | 1746-HSCE | AB | 1492-XIM4024-16R | AB | 1394C-AM04 | AB | 1336F-BRF75-AA-EN |
AB | 1746-HS | AB | 1492-IFM40F | AB | 1394-AM07 | AB | 1336F-BRF50-AA-EN |