Customization: | Available |
---|---|
Usage: | PLC MODULE |
Type: | New and Original |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Emerson PLC MODULE VE3008 KJ2005X1-MQ2 13P0072X082 MQ Controller
VE3008 INTRODUCTION
The VE3008 MQ Controller provides communication and control between the field devices and the other nodes on the control network. Control strategies and system configurations created on earlier DeltaV™ systems can be used with this powerful controller. The MQ Controller provides all the features and functions of the MD Plus Controller, with the same amount of memory. The control languages executed in the controllers are described in the Configuration Software Suite product data sheet.
VE3008 Benefits
Increases productivity The MQ Controller is as quick as the MD Plus Controller and provides the same configurable memory as the MD Plus controller. The Ethernet ports are full duplex, 100MB/second maximum throughput. The results are lower CPU utilization and higher capacity for control strategies.
Self-addressing. The DeltaV controller is unique in its ability to automatically identify itself to the DeltaV control network. When the controller is powered up, it is automatically assigned a unique address-no dip switches, no configuring-just plug and play!
Self-locating. A controller's physical location is easy to find. LEDs on the face of the controller can be made to flash, providing a strong visual clue.
Automatic I/O detection. The controller can identify all I/O interface channels located on the subsystem. As soon as an I/O interface is plugged in, the controller knows the general characteristics of the field devices managed by that I/O interface. This reduces the no value engineering associated with configuration - easy!
Connect to Electronic Marshalling and Wireless I/O. Starting in DeltaV v14.3, CHARMs and wireless devices connected through CHARM I/O Cards (CIOC) and Wireless I/O Cards (WIOC) can be assigned to the MQ controller. This makes it easier than ever to add I/O to an existing controller by simply adding a CIOC and/or WIOC to the DeltaV Area Control Network.
VE3008 image is for reference only product style, specific data of manufacture and product version, please refer to the actual product delivery!
Power, Mounting, and Memory | |
Power requirement | Supplied by System Power Supply through 2-wide Power/Controller Carrier |
Fuse protection | 3.0 A, non-replaceable fuses |
Power dissipation | 5.0 W typical. 7.0 W maximum |
Mounting | On right slot of power/controller carrier. |
User Memory | 48 MB |
Primary Control Network | &pin RJ-45 connector |
Redundant Control Network | 8-pin RJ-45 8nnector |
LED Indicators (ON Status) | |
Green - Power | Indicates DC power is applied. |
Red - Error | Indicates an error condition. |
Green - Active | Indicates that the controller is operating as the primary controller. |
Green - Standby | Indicates that the controller is operating as a backup controller (reserved for future use). |
Yellow flashing - Pri. CN | Indicates valid primary control network communication. |
Yellow, flashing - Sec. CN | Indicates valid secondary control network communication. |
All except Power flashing | Visual identification of controller initiated from user interface software by p/ng comma nd. |
All except Power flashing, alternating even and odd | Firmware upgrade in progress. |
Environmental | |
Operating temperature | -40° to 70° C (-40° to 158° F) |
Storage temperature | -40° to 85° C (-40.to 185° F) |
Relative humidity | 5 to 95%, non-condensing |
Airborne contaminants | ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating |
Shock (normal operating conditions) | 10 g sine wave for 11 ms |
Hazardous arealocation Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for information on installing in hazardous areas. | ATEX EEx nA IIC T4 Class 1, Div 2. Groups A. B. C, D. T4 |
Vibration (operative limit) | 1 mm peak-to-peak from 5 Hz to 16 H 0.5 g from 16 Hz to 150 Hz |
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for VE3008 KJ2005X1-MQ2 13P0072X082
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
KJ3001X1-BB1 DI, 8-Channel, 24 VDC, Dry Contact Card | KJ4001X1-CC1 4-Wire Terminal Block |
KJ3001X1-BG1 DO, 8-Channel, 24 VDC, Isolated Card | KJ4001X1-CD1 10 Pin Mass Terminal Block |
KJ3001X1-BJ1 DO, 8-Channel, 24 VDC, High Side Card | KJ4001X1-CE1 16 Pin Mass Terminal Block |
KJ3001X1-CA1 DI, 32-Channel, 24 VDC, Dry Contact Card | KJ4001X1-CF1 24 Pin Mass Terminal Block |
KJ3001X1-CB1 DO, 32-Channel, 24 VDC, High- Side Card | KJ4001X1-CG1 Thermocouple Terminal Block |
KJ3002X1-BA1 2-Wire AI, 8-Channel, 4-20 mA, HART Card | KJ4001X1-CH1 RTD Terminal Block |
KJ3002X1-BA1 4-Wire AI, 8-Channel, 4-20 mA, HART Card | KJ4001X1-CJ1 32 Channel Terminal Block |
KJ3002X1-BB1 AO, 8-Channel, 4-20 mA Card | KJ4001X1-HA1 Horizontal LocalBus Cable Extender |
KJ3002X1-BC1 2-Wire AI, 8-Channel, 4-20 mA Card | KJ4001X1-JA1 I/O Switchover Panel |
KJ3002X1-BC1 4-Wire AI, 8-Channel, 4-20 mA Card | KJ4001X1-NA1 Horizontal LocalBus Dual Right Cable Extender |
KJ3002X1-BD1 AI, 8-Channel, 1-5 VDC Card | KJ4001X1-NB1 Horizontal LocalBus Dual Left Cable Extender |
KJ3002X1-BE1 AO, 8-Channel, 4-20 mA, HART Card | KJ4002X1-BA1 Left 8 Wide Vertical Carrier |
KJ3002X1-BF1 RTD Card | KJ4002X1-BB1 Right 8 Wide Vertical Carrier |
KJ3002X1-BG2 Thermocouple, mV Card | KJ4002X1-BC2 Top 4 Wide Vertical Carrier |
KJ3003X1-BA1 Serial Interface Card | KJ4002X1-BD2 Bottom 4 Wide Vertical Carrier |
KJ3003X1-EA1 Serial Interface Terminal Block | KJ4002X1-BE1 Top Extender Cable Assembly |
KJ3004X1-EA1 Fieldbus H1 Terminal Block | KJ4002X1-BF1-4 Bottom Extender Cable Assembly |
KJ3005X1-BA1 AS-i Card | KJ4003X1-BA1-BB1 Left/Right 8 Wide VerticalPLUS Carrier |
KJ3006X1-BA1 Multifunction I/O Card | KJ4003X1-BC1 4 Wide VerticalPLUS Power/Controller Carrier |
KJ3007X1-BA1 ProfibusDP Card | KJ4003X1-BD1 4 Wide VerticalPLUS SISNet Repeater Carrier |
KJ3007X1-EA1 ProfibusDP Terminal Block | KJ4003X1-BE1-BF1 Right/Left 1 Wide VerticalPLUS Carrier Extender |
KJ3008X1-BA1 SOE Card | KJ4003X1-BG1 4 Wide VerticalPLUS Power Carrier |
KJ3009X1-BA1 DeviceNet Card | KJ4003X1-BH1-BH2 VerticalPLUS Standard/Short Cable |
KJ3201X1-BA1 DI, 8-Channel, 24 VDC, Dry Contact Series 2 Card | KJ4010X1-BF1 Left LocalBus Extender Cable Assembly |
KJ3201X1-EA1 Redundant Discrete Terminal Block | KJ4010X1-BG1 Right LocalBus Extender Cable Assembly |
KJ3202X1-BA1 DO, 24 VDC, High-Side, Series 2 Card | KJ4020X1-BD1 Fieldbus Power Conditioner |
KJ3203X1-BA1 DI, 32-Channel, 24 VDC Dry Contact Series 2 Card | KJ6001X1-BA2 Fieldbus H1 Carrier with Enclosure |
KJ3204X1-BA1 DO, 32-Channel, 24 VDC High-Side Series 2 Card | KJ6001X1-CA2 Fieldbus H1 Carrier |
VE5001 12P0677X062 | VE4009 12P0914X062 |
KJ1501X1-BB1 12P0678X022 | KJ3004X1-BA1 12P0921X032 |
VE5008 12P2186X012 | VE4007 12P1064X102 |
VE5008 12P2186X042 | KJ3005X1-BA1 12P2047X022 |
VE6006 12P1710X012 | 12P2062X072 VE4014 |
KJ2002X1-BA1 12P1442X032 | KJ3007X1-EA1 12P2413X032 |