Customization: | Available |
---|---|
Condition: | New |
Customized: | Non-Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Honeywell TDC 3000 51403519-160 K4LCN-16 MEMORY PROCESSOR MODULE BOARD HG
Experion LCN System Architecture Overview
The diagram that follows is an example of a basic ELCN system that includes the following migration scenario:
1. A redundant pair of ELCN Bridge UEA boxes has been installed and connected to the LCN and FTE networks.
2. The Microsoft Windows based nodes (ESVT, ES-T, ACE-T, and E-APP) have been converted from LCNP4E-based nodes to run as Virtual Machines on x86 servers running Microsoft Windows operating system. These Virtual Machines have been provided with thin clients. The diagram shows a Honeywell Orion Console used for the control room thin clients.
3. The History Module has been virtualized to run as a Virtual Machine on an x86 server platform. The History Module can be Physical on x86 server platform with Server 2016.
4. The K4LCN-based ENIM has been converted to UEA hardware. Note that the LCN NIM, AM, EPLCG, NG and EHB with C300s can also be migrated to equivalent ELCN UEA nodes.
5. This example system requires the ELCN Bridge to get data from the remaining LCN NIM, AM, EPLCG, EHB and NG for the Experion System.
6. The K4LCN-based NG has been converted to UEA hardware. Note the details of the NG Planning, Installation, and Service are covered in the Experion Local Control Network Gateway Planning, Installation and Service Guide (HWDOC-X608-en-A).
51403519-160 image is for reference only product style, specific data of manufacture and product version, please refer to the actual product delivery!
Experion LCN Functional Overview
The ELCN is the Fault Tolerant Ethernet (FTE) version of the coaxial cable-based Classic LCN. ELCN architecture runs an existing, unmodified LCN system on a new platform. An Experion LCN node uses an emulated LCN personality and Ethernet encapsulated LCN communications. There is no coaxial cabling or LCNI device; instead, an emulated LCNI device is presented to the personality. This allows for a range of new deployment options for K4LCNbased subsystems (AM, ENIM, HM, PCLG/EPLCG, EHB and NG) and LCNP4-based subsystems (ES-T, ESVT, ACET, E-APP). Deployments may be virtual or hardware platforms.
The Universal Embedded Appliance, when used as an ELCN Bridge, provides access from the ELCN FTE networking environment to the legacy Classic LCN COAX networking environment during the migration process. ELCN Bridge redundancy enables either of the paired bridges to assume the role of primary device. A redundant bridge pair occupies consecutive LCN node numbers. The ELCN Bridge also includes security controls provided by the UEA platform on which it is based.
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for 51403519-160
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Honeywell | 621-2100R | Honeywell | 51402592-100 | Honeywell | 51401135-300 |
Honeywell | 621-1100RC | Honeywell | 51402573-250 | Honeywell | 51401052-100 |
Honeywell | 620-0036 | Honeywell | 51402573-150 | Honeywell | 51309355-001 |
Honeywell | 51454475-100 | Honeywell | 51402573-100 | Honeywell | 51309228-300 |
Honeywell | 51405098-100 | Honeywell | 51402497-200 | Honeywell | 51309218-175 MC-TAMR03 |
Honeywell | 51404127-250 | Honeywell | 51401946-100 | Honeywell | 51309206-125 |
Honeywell | 51403988-150 | Honeywell | 51401642-150 | Honeywell | 51309152-175 MC-PAOX03 |
Honeywell | 51403776-100 | Honeywell | 51401635-150 | Honeywell | 51309152-175 |
Honeywell | 51403698-100 | Honeywell | 51401632-100 | Honeywell | 51308097-200 |
Honeywell | 51403645-400 | Honeywell | 51401594-200 | Honeywell | 51307687-176 |
Honeywell | 51403645-100 51403698-100 | Honeywell | 51401583-200 | Honeywell | 51307038-100 |
Honeywell | 51403626-200 | Honeywell | 51401583-100 | Honeywell | 51306975-175 |
Honeywell | 51403519-160 K4LCN-16 | Honeywell | 51401497-100 | Honeywell | 51306803-100 |
Honeywell | 51403299-200 | Honeywell | 51401496-100 | Honeywell | 51305896-200 |
Honeywell | 51402797-200 51305319-100 | Honeywell | 51401477-100 51402455-100 | Honeywell | 51305896-100 |
Honeywell | 51402755-100 K4LCN-4 | Honeywell | 51401477-100 | Honeywell | 51305890-175 |
Honeywell | 51402625-175 MC-PDIS12 | Honeywell | 51401381-100 | Honeywell | 51305776-100 |
Honeywell | 51402615-400 | Honeywell | 51401364-100 51401363-100 | Honeywell | 51305508-200 |
Honeywell | 51402592-175 | Honeywell | 51401286-100 | Honeywell | 51305508-200 |