ER5 Signal Conditioner Cards
Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards
Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests.
The signal conditioner cards can convert the I/O signals, isolate the I/O signals, and provide an isolated power supply from a built-in distributor.
For example, the measuring ranges of temperature and mV input signal conditioner cards can be changed by a portable BRAIN terminal.
Some cards have communication functions and supply power to BRAIN Series transmitters (BRAIN UNI, BRAIN ADMAG and BRAIN YEWFLO). You can select from 16 types of cards according to the kind of field signal.
Name |
mV input card |
Thermocouple input card |
Resistance thermometer sensor input card |
Potentiometer Input card |
Model |
EM1 |
ET5 |
ER5 |
ES1 |
Input signal |
DC vottage -50 to+150 mV |
TCJISC1602. IEC 60584-1 (ITS-90) Type K.T.J, E. B. R, S.N |
RTD (3-wire, Measunng current: 1mA) • JISC16O4: 2013, IEC 60751 (ITS-90) Pt100 •JIS 01604:1989, DIN (IPTS-68) Pt100 • JISC16O4: 1989JPt100 • JIS C1604:1981 Pt50 |
Potentiometer. 3-wire |
Measuring range |
Span |
10to100 mV DC |
10 to 63 mV (Thermoelectric conversion) (*1) |
10 to 650 °C (*2) |
Total resistance: 100 to 2000 Q Span: 80 to 2000 Q (*3) |
Zero elevation |
Smaller of 3 times span and ±50 mV |
Smaller of 3 times span and ±25 mV |
Max. 5 times span |
Within 50 % of total resistance |
Measuring range change |
Can be changed by BRAIN tenninal |
Input resistance |
1 MQ(10kQ when power off) |
1 MQ(10kQ when power off) |
- |
External input resistance |
500 Q max. |
Max. 150 Q/wire (*4) |
Max. 10Q/wire |
Allowable input voltage |
-0.5 to 4 V DC |
- |
- |
Input linearizabon |
None |
Provided |
Provided |
None |
Output signal |
1 to5 V DC. 2 outputs (output resistance: 1 Q max., load resistance: 2 kQ min.) |
Burnout |
Selectable (upscale, downscale) or off (can be changed by BRAIN), scaleout time less than 60 sec. |
Signal isolation |
Between input and output signals, input signal and power input Between output signal and power input |
Mounting method |
Mounted in speaal nest (signals and power supply are connected via backboard and connector) |
Wiring |
External wiring: M4 screw terminals for I/O in special nest Wiring to I/O cards: By special cable using connector |
External dimensions |
73 (Width)x24 (Height)x! 15 (Depth) mm (including knob) |
Weight |
0.10 kg or less |
Accuracy rating (*5) |
Within ±0.1 % of span |
Within larger of ±0.1 % of span and ±20 pV of input conversion |
Within larger of ±0.1 % of span and 0.2 °C |
Within ±0.1 % of span |
Reference junction compensation error |
- |
Type R. S: ±2 °C Other types: ±1 *C (*6) |
- |
- |
Isolation resistance |
Between input and output signals, input stgnal and power input: at 500 V DC, 100 MQ Between output signal and power input: at 500 V DC, 100 MQ |
Withstanding voltage |
Between input and output signals, input signal and power input: 1500 VAC for 1 minute Between output signal and power input: 500 V AC for 1 minute |
Power supply voltage |
24VDC±10% |
Max. current consumption (24 V DC) |
60 mA |
60 mA |
60 mA |
60 mA |
Ambient conditions |
0 to 50 ®C /5 to 90 % RH (non-condensing) |
Effect of ambient temperature change |
Max. ±0.2 % of span for 10 °C change |
Effect of power supply voltage change |
Max. ±0.1 % of span for change of 24 V DC ±10 % |
Accessory |
- |
Reference Junction Compensation Sensor (*7) |
- |
- |
*1: Measure range of Type B is 600 to 1700 °C.
*2: For JIS C 1604: 1989 JPt100, Span is 10 to 500 °C.
*3: Span must be at least 50 % of total resistance.
*4: Influence of external input resistance: ±0.1 °C/10 (3 lines should be in balance)
*5: Accuracy rating of #2 output: ±0.2 % (deviation from #1 output).
*6: For Type B, there is no reference junction compensation.
*7: Connected it to B and C terminals of signal conditioner.
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for ER5*C
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Amikon sells automation equipment around the world. With a strong focus on older, obsolete, Automation parts, we pride ourselves in providing high quality parts and services to our customers. Our goal is to provide a seamless purchasing experience that trumps the competition. Low lead time, with quick shipping and processing is our utmost concern. Reducing downtime is extremely important to us and our customers take notice! All orders are prepared by our expertly-skilled team and thoroughly vetted before each shipment.
We are specialized in providing world-reknowed brands: All-en Bradley, A-BB , Bently Nevada, GE ,Honeywell,Emerson, Triconex , Hima ,etc. Even some discontinued ones.We pride ourselves on being a leading provider of industrial automation parts and solutions. Extensive Inventory, Competitive Pricing, Fast Delivery, Global Reach and serves a diverse range of industries with 12 month warranty. Contact us today to learn more about how we can support your business needs.
We have a large inventory of spare parts for industrial control systems. Manufacturers cover a wide range and also work with a wide range of suppliers.Fast shipping to provide you with the best solution to meet your urgent needs If we don't have the stock request quotation you need, You can contact Sales Manager Stella help you
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
![Yokogawa PLC MODULE ER5*C ER5*B ET5* C ET5*B EH1*A EH0*A ECO*A RTD Input Module Signal Conditioner Cards](//www.micstatic.com/athena/img/transparent.png)
YOKOGAWA |
YHC4150X-01 YHC4150X |
YOKOGAWA |
SAI143-S63 |
YOKOGAWA |
KS1*B |
YOKOGAWA |
VM1*D S9210AQ-03 |
YOKOGAWA |
SAI143-S03 S2 |
YOKOGAWA |
IP91*A AS S9881BM-0 |
YOKOGAWA |
VI702 |
YOKOGAWA |
S9400UK |
YOKOGAWA |
FC11*A AS S9051BE-0 |
YOKOGAWA |
ST5*A |
YOKOGAWA |
RS81*B AS S9826AM-0 |
YOKOGAWA |
ET5*C |
YOKOGAWA |
ST4*D AS S9191AQ-0 |
YOKOGAWA |
PW482-S01 |
YOKOGAWA |
ET5*B |
YOKOGAWA |
ST3*D AS S9181AQ-0 |
YOKOGAWA |
PW482-50 S2 |
YOKOGAWA |
ER5*C |
YOKOGAWA |
SSB401-53 S1 |
YOKOGAWA |
PW482-10 S2 |
YOKOGAWA |
ER5*B |
YOKOGAWA |
SR1B-045N-1KC |
YOKOGAWA |
PW481-50 |
YOKOGAWA |
EH1*A |
YOKOGAWA |
SR1220E2 |
YOKOGAWA |
PW481-10 S2 |
YOKOGAWA |
EH0*A |
YOKOGAWA |
SPW482-E3 S1 |
YOKOGAWA |
PW302 S4 |
YOKOGAWA |
ECO*A |
YOKOGAWA |
SPW482-13 S1 |
YOKOGAWA |
PSCAIAAN |
YOKOGAWA |
EC401-10 S2 |
YOKOGAWA |
SDV541-S63 S3 |
YOKOGAWA |
PS31*A |
YOKOGAWA |
EC0*A AS E9740GA-02 |
YOKOGAWA |
SDV541-S53 S3 |
YOKOGAWA |
PC10031 |
YOKOGAWA |
EB501-50 S2 |
YOKOGAWA |
SDV531-S23 S1 |
YOKOGAWA |
NP53*C |
YOKOGAWA |
EB401-50 S1 |
YOKOGAWA |
SDV144-S53 S4 |
YOKOGAWA |
NP53*A |
YOKOGAWA |
EB401-10 S1 |
YOKOGAWA |
SDV144-S33 |
YOKOGAWA |
NFLR121-S51 S1 |
YOKOGAWA |
EA1*A AS E9740A-07 |
YOKOGAWA |
SDV144-S13 S2 |
YOKOGAWA |
MX3*D |
YOKOGAWA |
DX11*A S9081BE-0 |
YOKOGAWA |
SCP461-51 S2 |
YOKOGAWA |
MX2*D |
YOKOGAWA |
DX11*A |
YOKOGAWA |
SB401-50 S1 |
YOKOGAWA |
MRI-234*B |
YOKOGAWA |
DP97*B AS S9032AL-0 |
YOKOGAWA |
SB401-10 S1 |
YOKOGAWA |
MR6-16-2*A MR6-16-2*A/BU |
YOKOGAWA |
DP97*B |
YOKOGAWA |
SAI533-H33/PRP S1 |
YOKOGAWA |
MAC2*B AS S9310AQ-05 |
YOKOGAWA |
CP461-50 S2 |