Honeywell MU-PLAM02 51304362-100 Low Level Analog Input Multiplexer Processor CPU
Low Level Analog Input Multiplexer Processor .32 Inputs MU-PL AM02 | |
Data Conversion Performance (General Specifications) | |
Parameter | Specification |
FTA Models | WU_TAMR03, TAMT03, TAMT13 |
Input Type | Thermocouple, RTD, and linear millivolts |
Input Channels | 32 galvanicalll isolated |
A/D Converter Resolution | 14 bits TC types J, K, E, T,B, S, R, RP: 10 μV per bit 100 Q2 and 120 Q RTDs: 64 mQ per bit 10Q2RTD: 8 mQ2 per bit Linear mV sensors: 20 μV per bit |
CMV, dc to 60 Hz | 250 Vac Peak or +250 Vdc |
Dielectric Strength | 1500 Vac ms or 1500 Vdc cannen-t-canne (operatin), and channel-to-PMAPMHPM common (not operating) |
Crosstalk, dc to 60 Hz | 120 dB |
Input Impedance | 2M2min.@100mV |
Maximum Normal Mode Continuous Input (No damage) | -1 Vto 10V |
Input Scan Rate | 32 samples per second (each channel once per second) |
Line Frequency Synchronization | Configurable to 50 or 60 Hz |
Hardware (only) Accuracy | 40 puV, or t 160 ma 23.5"+2*C |
(1) Sofware (only) Accuracy | +0.19C typical, t0.5*C maximum at 23.5* t2*C |
Surge withstand capabillty (common mode) | ANSIEEE C37.90.1-1978 |
(1) Software EU conversion error including sofware reference junction compensation, at reference temperature. The temperature conversion by software meets or exceeds the accuracy tolerances for fth order polynomials as specifed in the National Institute of Standards and Technology (NIST) Monograph 125 (IPTS-68). | |
NOTE: Mercury-Wetted Relays are used in this product. |
51304362-100image is for reference only product style, specific data of manufacture and product version, please refer to the actual product delivery!
Low Level Analog Input Multiplexer Processor - 32 Inputs (continued) MU-PLAM02 | |
Data Conversion Performance--Resistive Temperature Device (RTD) | |
Parameter | Specification |
RTD (3 Wire) Input Signal Range Pt: 100 02 DIN (4376) Pt: 100 2 JIS (C-1604) N: 120 Q Ed #7 Cu: 10Q2 | -200 to 850°C -200 to 650°C -45 to 315"C -20 to 250°C |
CMRR, dc to 60 Hz (0-100 mV) | 102 RTD: 120 dB min. 1002 RTD: 110 dB min. |
NMRR, at line frequency (50 or 60 Hz) | 102 RTD: 60 dB min. (for 50/60 Hz noise of 0-15 mV) 1002 RTD: 60 dB min. (for 50/60 Hz noise of 0-75 mV) |
NMRR, at other than line frequency 100RTD: (0-15 mV) 1000 RTD: (0-75 mV) | Sn (ntr*t) NMRR = -20 xiog10 Where: \ (r*f*t) m= 3.14159 f= Noise Frequency t= Integration Time (20 ms @ 50 Hz, 16.66ms @ 60 Hz) |
Hardware Reference Junction Accuracy | +1.0*C maximum at 23.5* t2*C (in cabinet) |
Temperature Stability RTD Input | 30 ppm/°C RSS 40 ppm/C maximum |
RTD Max Lead Resistance | 15 2 |
CMRR = Common Mode Rejection Rato. NMRR = Normal Mode Rejection Ratio. |
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for MU-PLAM02 51304362-100
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Honeywell | 621-2100R | Honeywell | 51402592-100 | Honeywell | 51401135-300 |
Honeywell | 621-1100RC | Honeywell | 51402573-250 | Honeywell | 51401052-100 |
Honeywell | 620-0036 | Honeywell | 51402573-150 | Honeywell | 51309355-001 |
Honeywell | 51454475-100 | Honeywell | 51402573-100 | Honeywell | 51309228-300 |
Honeywell | 51405098-100 | Honeywell | 51402497-200 | Honeywell | 51309218-175 MC-TAMR03 |
Honeywell | 51404127-250 | Honeywell | 51401946-100 | Honeywell | 51309206-125 |
Honeywell | 51403988-150 | Honeywell | 51401642-150 | Honeywell | 51309152-175 MC-PAOX03 |
Honeywell | 51403776-100 | Honeywell | 51401635-150 | Honeywell | 51309152-175 |
Honeywell | 51403698-100 | Honeywell | 51401632-100 | Honeywell | 51308097-200 |
Honeywell | 51403645-400 | Honeywell | 51401594-200 | Honeywell | 51307687-176 |
Honeywell | 51403645-100 51403698-100 | Honeywell | 51401583-200 | Honeywell | 51307038-100 |
Honeywell | 51403626-200 | Honeywell | 51401583-100 | Honeywell | 51306975-175 |
Honeywell | 51403519-160 K4LCN-16 | Honeywell | 51401497-100 | Honeywell | 51306803-100 |
Honeywell | 51403299-200 | Honeywell | 51401496-100 | Honeywell | 51305896-200 |
Honeywell | 51402797-200 51305319-100 | Honeywell | 51401477-100 51402455-100 | Honeywell | 51305896-100 |
Honeywell | 51402755-100 K4LCN-4 | Honeywell | 51401477-100 | Honeywell | 51305890-175 |
Honeywell | 51402625-175 MC-PDIS12 | Honeywell | 51401381-100 | Honeywell | 51305776-100 |
Honeywell | 51402615-400 | Honeywell | 51401364-100 51401363-100 | Honeywell | 51305508-200 |
Honeywell | 51402592-175 | Honeywell | 51401286-100 | Honeywell | 51305508-200 |