Bently Nevada 1900/65A 172323-01 1900/65A 167699-02 General Purpose Equipment Monitor Module
The 1900/65A General Purpose Equipment Monitor is designed to continuously monitor and protect equipment that is used in a variety of applications and industries. The monitor's low cost makes it an ideal solution for generalpurpose machines and processes that can benefit from continuous monitoring and protection.
Inputs
The 1900/65A provides four transducer inputs and four temperature inputs. Software can configure each transducer input to support 2- and 3-wire accelerometers, velocity sensors or proximity sensors. Each temperature input supports Type E, J, K, and T thermocouples, and 2- or 3-wire RTDs.
Outputs
The 1900/65A provides six relay outputs, four 4-20 mA recorder outputs, and a dedicated buffered output. The user can use the 1900 Configuration software to configure the relay contacts to open or close according to the OK, Alert and Danger statuses of any channel or combination of channels, and to provide data from any variable from any channel on any recorder output. The dedicated buffer output can provide the signal for each transducer input.
1900/65A image is for reference only product style, specific data of manufacture and product version, please refer to the actual product delivery!
A Modbus Gateway option allows the monitor to provide static variables, statuses, event list, time and date information directly to any Modbus client, including Distributed Control Systems (DCSs), Supervisory Control and Data Acquisition (SCADA) systems, Programmable Logic Controllers (PLCs), or System 1 software. The monitor uses an internal counter and a Modbus client/master time reference to generate time and date information. Users can upgrade monitors without the Modbus Gateway by ordering the 1900/01 Communications Upgrade (see the Ordering Information section). The 1900/65A supports Modbus communications via Ethernet and a software-configurable RS232/485 serial port.
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for 1900/65A
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Bently Nevada | VELOMITOR 330500 330500-03-00 | Bently Nevada | 990-05-XX-03-CN 104M6732-01 | Bently Nevada | 84661-33 |
Bently Nevada | TK-3E 177313-02-02 | Bently Nevada | 990-05-XX-03-CN 104M1359-01 | Bently Nevada | 84661-17 |
Bently Nevada | TACH100-01 174652-01 | Bently Nevada | 990-05-XX-03-05 147202-01 | Bently Nevada | 84661-10 |
Bently Nevada | RS901104-03-050-10-01 R200602-400808 | Bently Nevada | 990-05-XX-01-CN | Bently Nevada | 84510-33 |
Bently Nevada | RS900106-05-30-05-02-00 | Bently Nevada | 990-05-XX-01-CN | Bently Nevada | 84152-01 |
Bently Nevada | JNJ5300-08-06-005-030-05-00-00-03 | Bently Nevada | 990-05-XX-01-00 MOD:165335-01 | Bently Nevada | 84147-01 |
Bently Nevada | JNJ5300-08-045-00-00 | Bently Nevada | 990-05-XX-01-00 MOD:147202-01 | Bently Nevada | 84145-01 |
Bently Nevada | JNJ5300-08-03-000-060-10-00-00-03 | Bently Nevada | 990-05-70-02-05 | Bently Nevada | 84140-01 |
Bently Nevada | HI-POTTED 00270143 PX4995 | Bently Nevada | 990-05-70-02-01 | Bently Nevada | 82926-01 |
Bently Nevada | ARS-2102 ARS2102 | Bently Nevada | 990-05-70-02-00 | Bently Nevada | 82367-01 |
Bently Nevada | 991-25-XX-01-CN | Bently Nevada | 990-05-50-01-05 | Bently Nevada | 82365-01 |
Bently Nevada | 991-06-XX-01-00 MOD:169955-01 | Bently Nevada | 990-04-XX-01-00 MOD:147202-01 | Bently Nevada | 81725-02 |
Bently Nevada | 991-06-XX-01-00 169955-01 | Bently Nevada | 990-04-70-02-00 | Bently Nevada | 81724-00-08-10-02 |
Bently Nevada | 991-06-70-01-CN | Bently Nevada | 990-04-70-01-05 | Bently Nevada | 81546-01 |
Bently Nevada | 991-06-70-01-00 | Bently Nevada | 990-04-70-01-00 | Bently Nevada | 81545-01 |
Bently Nevada | 991-06-50-01-00 | Bently Nevada | 990-04-70-01-00 | Bently Nevada | 81545-01 |
Bently Nevada | 991-06-50-01-00 | Bently Nevada | 990-04-50-02-CN | Bently Nevada | 81544-01 |
Bently Nevada | 991-01-XX-02-05 | Bently Nevada | 990-04-50-02-00 | Bently Nevada | 81305-040-00 |
Bently Nevada | 991-01-XX-01-CN | Bently Nevada | 990-04-50-01-00 | Bently Nevada | 76686-040-01 |
Bently Nevada | 991-01-XX-01-CN | Bently Nevada | 9200-06-05-10-00 | Bently Nevada | 76683-90 |
Bently Nevada | 991-01-XX-01-05 MOD:284318-01 | Bently Nevada | 9200-06-05-05-00 | Bently Nevada | 76683-50 |
Bently Nevada | 991-01-XX-01-01 MOD:284318-01 | Bently Nevada | 9200-03-05-10-00 | Bently Nevada | 76680-00-06-50-0-2 |