HIMATRIX PLC Module F3501030 F3501130 F2DO801 F2DO1602 F60DI3201 Safety-Related Controller Safety Remote I/O Module Brand new
Product Description
HIMATRIX F35 010 30
Product Data HIMatrix F35 010 30 (-20 °C)
The HIMatrix F35 010 30 model variant is intended for use at the extended temperature range of -20…+60 °C. The electronic components are coated with a protective lacquer.

HIMATRIX F35 011 30
| HIMatrix F35 011 (-20 °C) |
| Operating temperature |
-20...+60 °C |
| Weight |
1.2 kg |
| Designation |
Description |
Part no. |
| F35 01 |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature 0...+60 ºC, for ELOP II Factory programming tool |
98 2200416 |
| F35 011 (-20 ºC) |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature -20...+60 ºC, for ELOP II Factory programming tool |
98 2200453 |
| F35 012 (subsea / -20 ºC) |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature -20...+60 ºC, designed for subsea-use according to ISO 13628-6: 2006, for ELOP II Factory programming tool |
98 2200454 |
| F35 01 SILworX |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature 0...+60 ºC, for SILworX programming tool |
98 2200473 |
| F35 011 SILworX (-20 ºC) |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature -20...+60 ºC, for SILworX programming tool |
98 2200476 |
| F35 012 SILworX (subsea / -20 ºC) |
Compact controller with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs, operating temperature -20...+60 ºC, designed for subsea-use according to ISO 13628-6: 2006, for SILworX programming tool. |
98 2200477 |
F2 DO8 01
Product Description
The safety-related F2 DO 8 01 remote I/O is a compact system located in a metal enclosure with 8 safety-related relay outputs.
The remote I/O is available in a model variant for SILworX and a model variant for ELOP II Factory. All variants are described in this manual.
The remote I/O serves to extend the I/O level of the HIMax and HIMatrix controllers, and is connected to them via safeethernet. The remote I/O itself is not able to run a user program. The HIMatrix remote I/Os are not multi-master capable. The remote I/O is suitable for mounting in Ex-zone 2, see Chapter 4.1.2. The device has been certified by the TÜV for safety-related applications up to SIL 3 (IEC 61508, IEC 61511 and IEC 62061), Cat. 4 (EN 954-1) and PL e (EN ISO 13849-1). Further safety standards, application standards and test standards are specified in the
certificate available on the HIMA website.
Safety Function
The remote I/O is equipped with safety-related relay outputs. These outputs are safely assigned their values by the connected controller via safeethernet.

F2 DO 16 02
Product Description
The safety-related F2 DO 16 02 remote I/O is a compact system in a metal housing with 16 safety-related relay outputs.
| Desig nation |
Descripti on |
| F2 DO 16 02 |
Remote I/O (16 relay outputs up to 30 VAC/ 60 VDC), Operating temperature: 0...+60 °C, for ELOP II Factory programming tool |
| F2 DO 16 02 SILworX |
Remote I/O (16 relay outputs up to 30 VAC/ 60 VDC), Operating temperature: 0...+60 °C, for SILworX programming tool |
F60 DI 32 01
The DI 32 01 is a module with 32 digital inputs and is used for the modular F60 system. The inputs are galvanically separated to the I/O bus.
Line Control
Line control is used to detect short-circuits or open-circuits, e.g., on EMERGENCY STOP inputs complying with Cat. 4 and PL e in accordance with EN ISO 13849-1. Line control can be configured for the F60 system.
Application example: The outputs DO 1 and DO 2 of the DIO 24/16 01 module are connected to the digital inputs (DI) of the same module or of the F60 DI 32 01 module as follows:

The digital outputs are pulsed. This allows monitoring of the wires to the digital inputs of the F60 DI 32 01 or F60 DIO 24/16 01 module.
A fault reaction is triggered if one of the following faults occurs:
- Cross-circuit between two parallel wires.
- Improper connections of two lines (e.g., TO 2 to DI 3).
- Earth fault of a line (with earthed ground only).
- Open-circuit or open contacts, i.e., including when one of the two EMERGENCY STOP switches mentioned above has been engaged.
The fault reaction includes the following actions:
- The ERROR LED on the controller's front plate blinks.
- The inputs are set to 0.
- An evaluable error code is created.

Safety-Related Controller
Hima Safety-Related Controller
All safety information, notes and instructions specified in this document must be strictly observed. The product may only be used if all guidelines and safety instructions are adhered to. This product is operated with SELV or PELV. No imminent risk results from the product itself. The use in Ex-zone is permitted if additional measures are taken. The following safety information, notes and instructions must be strictly observed. The product may only be used if all guidelines and safety instructions are adhered to.This product is operated with SELV or PELV. No imminent danger results from the product itself. The use in Ex-Zone is permitted if additional measures are taken.
Intended Use
HIMatrix components are designed for assembling safety-related controller systems. When using the components in the HIMatrix system, comply with the following general requirements.
Residual Risk
No imminent risk results from a HIMatrix system itself.
Residual risk may result from:
- Faults related to engineering
- Faults related to the user progra
- Faults related to the wiring
Safety Precautions
Observe all local safety requirements and use the protective equipment required on site.
Emergency Information
A HIMatrix system is a part of the safety equipment of a site. If a device or a module fails, the system enters the safe state.
In case of emergency, no action that may prevent the HIMatrix systems from operating safely is permitted.

Whole sale pictures
FAQ
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for F2 DO 16 02
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add

Recommend
| HIMATRIX |
Z7150 |
HIMATRIX |
F7541 |
HIMATRIX |
F3226 |
| HIMATRIX |
Z7138 |
HIMATRIX |
F7133 |
HIMATRIX |
F3221 |
| HIMATRIX |
Z7136 |
HIMATRIX |
F7131 |
HIMATRIX |
F3113A |
| HIMATRIX |
Z7128 |
HIMATRIX |
F7130A |
HIMATRIX |
F3 AIO 8/4 01 |
| HIMATRIX |
Z7127 |
HIMATRIX |
F7130 |
HIMATRIX |
F2201 |
| HIMATRIX |
Z7126 |
HIMATRIX |
F7126 |
HIMATRIX |
F1101 |
| HIMATRIX |
Z7116 |
HIMATRIX |
F7105A |
HIMATRIX |
BV7032-0.5 |
| HIMATRIX |
Z7108 |
HIMATRIX |
F6705 |
HIMATRIX |
52100 |
| HIMATRIX |
Z1006 |
HIMATRIX |
F6251 |
HIMATRIX |
F3 DIO 16/801 |
| HIMATRIX |
K9203 |
HIMATRIX |
F6217 |
HIMATRIX |
F60 MI 24 01 |
| HIMATRIX |
K7214 |
HIMATRIX |
F6215 |
HIMATRIX |
F6706 |
| HIMATRIX |
F60GEH01 |
HIMATRIX |
F6205 |
HIMATRIX |
ZI006 |
| HIMATRIX |
F3DIO8/801 |
HIMATRIX |
F4204 |
HIMATRIX |
F1DI1601 |
| HIMATRIX |
F3 DIO 8/8 01 |
HIMATRIX |
F3430 |
HIMATRIX |
F3311 |
| HIMATRIX |
F2DO1602 |
HIMATRIX |
F3423 |
HIMATRIX |
F3225 |
| HIMATRIX |
H7506 |
HIMATRIX |
F3421 |
HIMATRIX |
F3222 |
| HIMATRIX |
F8651E |
HIMATRIX |
F3417A |
HIMATRIX |
F3112 |
| HIMATRIX |
F8650X |
HIMATRIX |
F3349 |
HIMATRIX |
F60DIO24/1601 |
| HIMATRIX |
F8641 |
HIMATRIX |
F3331 |
HIMATRIX |
F6251 |
| HIMATRIX |
F8627 |
HIMATRIX |
F3330 |
HIMATRIX |
F60DI3201 |
| HIMATRIX |
F8621 F8621/A |
HIMATRIX |
F3322 |
HIMATRIX |
F3D/O16/801 |
| HIMATRIX |
F8620 |
HIMATRIX |
F3237 |
HIMATRIX |
F3417A |
| HIMATRIX |
F7553 |
HIMATRIX |
F3236 |
HIMATRIX |
F6214 |
| HIMATRIX |
F1DI16 01 |
HIMATRIX |
F3334 |
HIMATRIX |
F8627X |
| HIMATRIX |
F8628X |
HIMATRIX |
F3AIO8/401 |
HIMATRIX |
F3 DIO 8/8 01 |
| HIMATRIX |
F60 DIO 24/16 |
HIMATRIX |
F2 DO 16 02 |
HIMATRIX |
F60 GEH 01 |
Amikon sells new and surplus products and develops channels to purchase such products. This website is not approved or endorsed by any of the listed manufacturers or trademarks.
Amikon is not an authorized distributor, distributor or representative of the products displayed on this website. All product names, trademarks, brands and logos used on this website are the property of their respective owners. The description, description or sale of products with these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.