42300
Equipment and type:
Planar 4 System Modules
12100, 13110, 22100, 22120, 22121, 32100, 32101, 32102, 32103, 32110, 42100, 42110, 42200, 42300, 42400, 42500, 52100, 52110, 62100, 80105, 80106, 80107, 80110, 90100, 90300, 90900, 90901, 90910, 90911, K9203A
The type designation of the modules consists of five digits. It is defined according to the following code:
| 1 |
2 |
Digit 3 |
4 |
5 |
Allocation |
| 1 |
|
|
|
|
In put modules |
| 2 |
|
|
|
|
Output modules |
| 3 |
|
|
|
|
Relay modules |
| 4 |
|
|
|
|
Logic function modules |
| 5 |
|
|
|
|
Timer function modules |
| 6 |
|
|
|
|
Analogue modules |
| 7 |
|
|
|
|
|
| 8 |
|
|
|
|
Communication modules |
| 9 |
|
|
|
|
Power supply, accessories |
| |
0 |
|
|
|
No certification |
| |
1 |
|
|
|
(Ex)i certificate |
| |
2 |
|
|
|
TUV certificate fs, safety-related |
| |
3 |
|
|
|
(Ex)i and TUV certificate fs |
| |
4 |
|
|
|
|
| |
|
0...9 |
0...9 |
|
Sequential numbers 00…99 |
| |
|
|
|
0 |
Base version |
| |
|
|
|
1...9 |
Versions |
52100
Product:Automation Equipment, Safety Related Modules of the Planar 4 system
Model(s):PLANAR 4 52100 and 62100 modules
Parameters:The report H883629T in the current valid revision are mandatory part of this certificate. The product cornplies
with the following safety requirements only if the specifications documented in the currently valid revision of this report are met.
Tested according to: IEC 61 508-1 :201 0 (SlL4) IEC 61 508-2:201 0 (SlL4) IEC 61 508-3:201 0 (SlL4) IEC 515084:2010 (SlL4)
H4135A
H 4135: Relay in an electronic housing
safety_related, for circuits up to SIL 3 according to IEC 61508

Figure 1: Block diagram
The module is tested according to
-IEC 61508/SIL 3,
EN 298
DIN VDE 0116,EN 50156,
NFPA8501,NFPA 8502
-EN 60664,DINEN 50178(VDE 0160),
EN 6100-6-2,EN 50082-2,EN 61000-6-4
-(DIN V19250/RC1...6,DINVDE 0801 incI.A1)
The relay is suitable for the switching of safety-related circuits. Thus the relay can be used for safety shutdowns, e. g. to cut off the entire fuel supply for combustion plants. The module is equipped with relays in diversity.
The module has six fused current paths providing the line protection and the power supply for the module subframes.
Fuses max. 4 A-T (delivery state) floating changeover contact
Relay data: cf. reverse
Switching time approx. 60 ms
Operating data 24 V DC / -15...+20 %, rpp < 15 %, 65 mA
Ambient conditions -25...+70 °C
Space requirement 4 TE - H 100 F 32.101
F3 DIO 8/8 01
Product Description
The safety-related F3 DIO 8/8 01 remote I/O is a compact system in a metal housing with 8 digital inputs, 8 digital DO+ outputs (L- ground), 2 digital DO- outputs (S+ ground) and 2 pulsed outputs. The digital outputs DO4+, DO8+, DO4- and DO8- can also be connected as
2-pole connections.The remote I/O is available in various model variants for SILworX and ELOP II Factory, see Table 4. Remote I/Os are connected to individual HIMax or HIMatrix controllers via safeethernet. They are used to extend the I/O level, but are not able to run any user program by themselves. The remote I/O is suitable for mounting in Ex-zone 2. The device is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508, IEC 61511 and IEC 62061), Cat. 4 and PL e (EN ISO 13849-1) and SIL 4 (EN 50126, EN 50128 and EN 50129). Further safety standards, application standards and test standards are specified in the certificates available on the HIMA website.
Equipment, Scope of Delivery
The following table specifies the available remote I/O variants:
Table 4: Available Variants
| Designation |
Description |
| F3 DIO 8/8 01 |
Remote I/O (8 digital inputs, 8 digital outputs, 2 pulsed outputs), Operating temperature: 0...+60 °C, for ELOP II Factory programming tool |
| F3 DIO 8/8 014 |
Remote I/O (8 digital inputs, 8 digital outputs, 2 pulsed outputs), Operating temperature:25...+70 °C (temperature class T1), Vibration and shock tested according to EN 50125-3 and EN 50155, class 1B according to I EC 61373, for ELOP II Factory programming tool |
| F3 DIO 8/8 01 SILworX |
Remote I/O (8 digital in puts, 8 digital outputs, 2 pulsed outputs), Operating temperature: 0...+60 °C, for SILworX programming tool |
| F3 DIO 8/8 014 SILworX |
Remote I/O (8 digital in puts, 8 digital outputs, 2 pulsed outputs), Operating temperature: -25...+70 °C (temperature class T1), Vibration and shock tested according to EN 50125-3 and EN 50155, class 1B according to IEC 61373, for SILworX programming tool |
Assembly
This chapter describes the layout and function of the remote I/Os, and their communication via safeethernet.


1.Digital Outputs (L+ Switching)
2.Safety-Related Processor System (CPU)
3.Switch
4.Watchdog
5.Digital Inputs
6.Digital Outputs (L- Switching)
7.Pulsed Outputs
K 7214

1.Air intake filter mounted in the control cabinet door
2.Air flow
3.Fuse and power distribution modules K 7205, K 7206, K 7212, K 7213 or K 7214
4.Air exhaust through the HIMA K 9202B cabinet fan for mounting on the top internal section
of the control cabinet
5.Required clearance for air intake and air exhaust
Supply of the H51X Base Rack
For supply and power distribution, HIMA recommends using the following components:
K 7214: Redundant supply up to a maximum of 150 A total current with fuse protection of up to 18 individual circuits with circuit breakers.
Z 7126
System cables with cable plugs
The HIQuad X -PLC- system cables are used to wire the connector of the I/O Modules with the Marshalling cabinets or
with the Field Accessory.
•Z 7126/6706/.. Module F6706
•Z 7063/6221/.. Module F6221
•Z 7126/6705/.. Module F6705
BV 7032-0.5
I/O bus, B 5233-1
| Connection |
Procedure |
| XD.1 to XD.2 |
Connect together with BV 7032 |
| XD.4 |
Remove F 7546 and plug it on XD.2 of the last I/O rack Connect BV 7032 and plug it on XD.1 1st I/O rack |
| Connection |
Procedure |
| XD.3 and XD.4 |
Remove F 7546 and plug it on XD.2 of the last I/O rack of both I/O buses |
| XD.4 |
Connect BV 7032 and plug it on XD.1 of the 1st I/O rack in the 1st I/O bus |
| XD.3 |
Connect BV 7032 and plug it on XD.1 of the 1st I/O rack in the 2nd I/O bus |
Safety System
Safety Function
The remote I/O is equipped with safety-related digital inputs and outputs. The input values on the inputs are safely transmitted to the connected controller via safeethernet. The outputs are safely assigned their values by the connected controller via safeethernet.
Safety-Related Digital Inputs
The remote I/O is equipped with 8 digital inputs. The state (HIGH, LOW) of each input is signaled by an individual LED. Mechanical contacts without own power supply or signal power source can be connected to the inputs. Potential-free mechanical contacts without own power supply are fed via an internal short-circuit-proof 24 V power source (LS+). Each of them supply a group of 4 mechanical contacts. Figure 1 shows how the connection is performed. With signal voltage sources, the corresponding ground must be connected to the input (L-), see Figure 1.

Connection of potential-free mechanical contacts Connection of signal power sources
Figure 1: Connections to Safety-Related Digital Inputs
Interconnecting the Earth Terminals of Multiple Switchgear Cabinets
The remote I/O pulses the pulsed outputs to detect short-circuits and open-circuits on the lines connected to the digital inputs. To do so, configure the Value [BOOL] -> system variable in SILworX or the DO[01].Value system signal in ELOP II Factory. The variables for the pulsed outputs must begin with channel 1 and reside in direct sequence, one after the other. If the following faults occur, the FAULT LED located on the front plate of the device blinks, the inputs are set to low level and an (evaluable) error code is created:
- Cross-circuit between two parallel wires.
- Invalid connections of two lines (e.g., TO 2 to DI 3),
- Earth fault on one wire (with earthed ground only).
- Open-circuit or open contacts, i.e., including when one of the two EMERGENCY STOP switches mentioned above has been engaged, the FAULT LED blinks and the error code is created.

1.EMERGENCY STOP 1
2.EMERGENCY STOP 2
Safety-Related Digital Outputs
The remote I/O is equipped with 8 digital outputs DO+ (ground L-) and 2 digital outputs DO- (ground S+). The state (HIGH, LOW) of each output is signaled by an individual LED (HIGH, LOW). At the maximum ambient temperature, the DO+ outputs 1...3 and 5...7 can be loaded with 0.5 A each, and DO+ outputs 4 and 8 can be loaded with 1 A or with 2 A at an ambient temperature of up to 40 °C. At the maximum ambient temperature, the DO- outputs 4- and 8- can be loaded with 1 A each or with 2 A at an ambient temperature of up to 40 °C. Within a temperature range of 60…70 °C, all outputs of the F3 DIO 8/8 014 can be loaded with 0.5 A, see Table 15. The digital outputs DO4+, DO8+, DO4- and DO8- can be connected as one-pole or 2-pole switching connections. The remaining outputs are only set up for one-pole switching connections.
With 1-pole switching outputs, ensure that the system's L- ground from the corresponding channel group is used for the DO+ outputs and the system's S+ ground is used for the DOoutputs, see Table 18. The S+ ground is limited by the system to a maximum current of 8 A and
obtained from the 24 V voltage connection. The external wire of an output is not monitored, however, a detected short-circuit is signaled.
With 2-pole switching outputs, the L+ switching output DO4+ must be connected to the Lswitching output DO4- and the L+ switching output DO8+ to the L- switching output DO8-. This type of connection must be set via the DO2[xx].2-pole system parameter.
Figure 3: Connection to the 2-Pole Switching Outputs (DO-, DO+)
Whole sale pictures



FAQ
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for Z 7126
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add

Recommend
| HIMATRIX |
Z7150 |
HIMATRIX |
F7541 |
HIMATRIX |
F3226 |
| HIMATRIX |
Z7138 |
HIMATRIX |
F7133 |
HIMATRIX |
F3221 |
| HIMATRIX |
Z7136 |
HIMATRIX |
F7131 |
HIMATRIX |
F3113A |
| HIMATRIX |
Z7128 |
HIMATRIX |
F7130A |
HIMATRIX |
F3 AIO 8/4 01 |
| HIMATRIX |
Z7127 |
HIMATRIX |
F7130 |
HIMATRIX |
F2201 |
| HIMATRIX |
Z7126 |
HIMATRIX |
F7126 |
HIMATRIX |
F1101 |
| HIMATRIX |
Z7116 |
HIMATRIX |
F7105A |
HIMATRIX |
BV7032-0.5 |
| HIMATRIX |
Z7108 |
HIMATRIX |
F6705 |
HIMATRIX |
52100 |
| HIMATRIX |
Z1006 |
HIMATRIX |
F6251 |
HIMATRIX |
F3 DIO 16/801 |
| HIMATRIX |
K9203 |
HIMATRIX |
F6217 |
HIMATRIX |
F60 MI 24 01 |
| HIMATRIX |
K7214 |
HIMATRIX |
F6215 |
HIMATRIX |
F6706 |
| HIMATRIX |
F60GEH01 |
HIMATRIX |
F6205 |
HIMATRIX |
ZI006 |
| HIMATRIX |
F3DIO8/801 |
HIMATRIX |
F4204 |
HIMATRIX |
F1DI1601 |
| HIMATRIX |
F3 DIO 8/8 01 |
HIMATRIX |
F3430 |
HIMATRIX |
F3311 |
| HIMATRIX |
F2DO1602 |
HIMATRIX |
F3423 |
HIMATRIX |
F3225 |
| HIMATRIX |
H7506 |
HIMATRIX |
F3421 |
HIMATRIX |
F3222 |
| HIMATRIX |
F8651E |
HIMATRIX |
F3417A |
HIMATRIX |
F3112 |
| HIMATRIX |
F8650X |
HIMATRIX |
F3349 |
HIMATRIX |
F60DIO24/1601 |
| HIMATRIX |
F8641 |
HIMATRIX |
F3331 |
HIMATRIX |
F6251 |
| HIMATRIX |
F8627 |
HIMATRIX |
F3330 |
HIMATRIX |
F60DI3201 |
| HIMATRIX |
F8621 F8621/A |
HIMATRIX |
F3322 |
HIMATRIX |
F3D/O16/801 |
| HIMATRIX |
F8620 |
HIMATRIX |
F3237 |
HIMATRIX |
F3417A |
| HIMATRIX |
F7553 |
HIMATRIX |
F3236 |
HIMATRIX |
F6214 |
| HIMATRIX |
F1DI16 01 |
HIMATRIX |
F3334 |
HIMATRIX |
F8627X |
| HIMATRIX |
F8628X |
HIMATRIX |
F3AIO8/401 |
HIMATRIX |
F3 DIO 8/8 01 |
| HIMATRIX |
F60 DIO 24/16 |
HIMATRIX |
F2 DO 16 02 |
HIMATRIX |
F60 GEH 01 |
Amikon sells new and surplus products and develops channels to purchase such products. This website is not approved or endorsed by any of the listed manufacturers or trademarks.
Amikon is not an authorized distributor, distributor or representative of the products displayed on this website. All product names, trademarks, brands and logos used on this website are the property of their respective owners. The description, description or sale of products with these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.