HIMA PLC Module F3DIO8/801 F3DIO20/802 F60GEH01 F60MI2401 Safety-Related Remote I/O Module Brand New
F3 DIO 8/8 01
Product Description
The safety-related F3 DIO 8/8 01 remote I/O is a compact system in a metal housing with 8 digital inputs, 8 digital DO+ outputs (L- ground), 2 digital DO- outputs (S+ ground) and 2 pulsed outputs. The digital outputs DO4+, DO8+, DO4- and DO8- can also be connected as 2-pole connections.
Safety Function
The remote I/O is equipped with safety-related digital inputs and outputs. The input values on the inputs are safely transmitted to the connected controller via safeethernet. The outputs are safely assigned their values by the connected controller via safeethernet.
Reaction in the Event of a Fault
If the device detects a faulty signal on a digital output, the affected module output is set to the safe (de-energized) state using the safety switches. If a device fault occurs, all digital outputs are switched off. In both cases, the devices activates the FAULT LED. The error code allows the user to configure additional fault reactions in the user program.
F3DIO20/8 02
Product Description
The safety-related F3 DIO 20/8 02 remote I/O is a compact system located in a metal enclosure with 20 digital inputs and 8 digital outputs.
LED Indicators
The light-emitting diodes (LEDs) indicate the operating state of the remote I/O. The LEDs are classified as follows:
• Operating Voltage LED-
• System LEDs
•Communication LED
• I/O LEDs
Product Data of F3 DIO 20/8 02 021 (-20 °C)
The F3 DIO 20/8 02 021 (-20 °C) model variant is intended for use at the extended temperature range of -20…+60 °C. The electronic components are coated with a protective lacquer.
F60GEH01
The modular HIMatrix F60 system is composed of a subrack and various modules inserted in the subrack slots.
Slots 1 and 2 are reserved, all remaining slots can be freely occupied:
• The wide slot 1 is always occupied with the power supply module (PS 01).
• Slot 2 is always occupied with the CPU module (CPU 01).
• The remaining slots can be freely occupied with all remaining module types.
The modular system F60 can also be connected to HIMatrix compact systems via safeethernet.
Residual Risk
No imminent risk results from a modular HIMatrix F60 system itself.
Residual risk may result from:
• Faults related to engineering
• Faults related to the user program
• Faults related to the wiring
F60 MI 24 01
MI 24 01 is a plug-in module for the modular F60 HIMatrix system.
The MI 24 01 module has 24 digital input channels. The analog inputs AI are inputs for measuring currents of 0/4...20 mA. The digital inputs DI can be used with proximity switches in accordance with EN 60947-5-6, safety proximity switches or contacts (wired with resistors).
Pin Designation
The pin designation consists of column designation (A, B) and row designation (01, 02, 03, ...). 
Terminal Pin Channel 1
Terminal A 01: Supply 1 (S1+)
Terminal A 02: Ground 1 (I1-)
Terminal B 01: Digital Input 1 (DI1+)
Terminal B 02: Analog Input 1 (AI1+)
Status LED Channel 1
LED without Function
Terminal Pin Channel 4
Terminal Pin Channel 3 Term
Hima Safety-Related Controller
All safety information, notes and instructions specified in this document must be strictly observed. The product may only be used if all guidelines and safety instructions are adhered to. This product is operated with SELV or PELV. No imminent risk results from the product itself. The use in Ex-zone is permitted if additional measures are taken. The following safety information, notes and instructions must be strictly observed. The product may only be used if all guidelines and safety instructions are adhered to.This product is operated with SELV or PELV. No imminent danger results from the product itself. The use in Ex-Zone is permitted if additional measures are taken.
Intended Use
HIMatrix components are designed for assembling safety-related controller systems. When using the components in the HIMatrix system, comply with the following general requirements.
Residual Risk
No imminent risk results from a HIMatrix system itself.
Residual risk may result from:
- Faults related to engineering
- Faults related to the user progra
- Faults related to the wiring
Safety Precautions
Observe all local safety requirements and use the protective equipment required on site.
Emergency Information
A HIMatrix system is a part of the safety equipment of a site. If a device or a module fails, the system enters the safe state.
In case of emergency, no action that may prevent the HIMatrix systems from operating safely is permitted. 
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for F60 MI 24 01
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
| HIMATRIX | Z7150 | HIMATRIX | F7541 | HIMATRIX | F3226 |
| HIMATRIX | Z7138 | HIMATRIX | F7133 | HIMATRIX | F3221 |
| HIMATRIX | Z7136 | HIMATRIX | F7131 | HIMATRIX | F3113A |
| HIMATRIX | Z7128 | HIMATRIX | F7130A | HIMATRIX | F3 AIO 8/4 01 |
| HIMATRIX | Z7127 | HIMATRIX | F7130 | HIMATRIX | F2201 |
| HIMATRIX | Z7126 | HIMATRIX | F7126 | HIMATRIX | F1101 |
| HIMATRIX | Z7116 | HIMATRIX | F7105A | HIMATRIX | BV7032-0.5 |
| HIMATRIX | Z7108 | HIMATRIX | F6705 | HIMATRIX | 52100 |
| HIMATRIX | Z1006 | HIMATRIX | F6251 | HIMATRIX | F3 DIO 16/801 |
| HIMATRIX | K9203 | HIMATRIX | F6217 | HIMATRIX | F60 MI 24 01 |
| HIMATRIX | K7214 | HIMATRIX | F6215 | HIMATRIX | F6706 |
| HIMATRIX | F60GEH01 | HIMATRIX | F6205 | HIMATRIX | ZI006 |
| HIMATRIX | F3DIO8/801 | HIMATRIX | F4204 | HIMATRIX | F1DI1601 |
| HIMATRIX | F3 DIO 8/8 01 | HIMATRIX | F3430 | HIMATRIX | F3311 |
| HIMATRIX | F2DO1602 | HIMATRIX | F3423 | HIMATRIX | F3225 |
| HIMATRIX | H7506 | HIMATRIX | F3421 | HIMATRIX | F3222 |
| HIMATRIX | F8651E | HIMATRIX | F3417A | HIMATRIX | F3112 |
| HIMATRIX | F8650X | HIMATRIX | F3349 | HIMATRIX | F60DIO24/1601 |
| HIMATRIX | F8641 | HIMATRIX | F3331 | HIMATRIX | F6251 |
| HIMATRIX | F8627 | HIMATRIX | F3330 | HIMATRIX | F60DI3201 |
| HIMATRIX | F8621 F8621/A | HIMATRIX | F3322 | HIMATRIX | F3D/O16/801 |
| HIMATRIX | F8620 | HIMATRIX | F3237 | HIMATRIX | F3417A |
| HIMATRIX | F7553 | HIMATRIX | F3236 | HIMATRIX | F6214 |
| HIMATRIX | F1DI16 01 | HIMATRIX | F3334 | HIMATRIX | F8627X |
| HIMATRIX | F8628X | HIMATRIX | F3AIO8/401 | HIMATRIX | F3 DIO 8/8 01 |
| HIMATRIX | F60 DIO 24/16 | HIMATRIX | F2 DO 16 02 | HIMATRIX | F60 GEH 01 |