Customization: | Available |
---|---|
Task: | Check datasheet |
Structure: | Check datasheet |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Invensys TRICONEX 3706A 3708E THERMOCOUPLE ANALOG INPUT MODULE
3706A 3708E THERMOCOUPLE ANALOG INPUT MODULE Function
A thermocouple input (TC) module includes three independent input channels. Each input channel receives variable voltage signals from each point, performs thermocouple linearization and cold-junction compensation, and converts the result to degrees Celsius or Fahrenheit. Each channel then transmits 16-bit signed integers representing 0.125 degrees per count to the three main processors on demand. In TMR mode, a value is then selected using a mid-value selection algorithm to ensure correct data for every scan.
Each thermocouple input module is programmable to support one thermocouple type, selected from J, K and T for standard thermocouple input modules and from J, K, T and E for Failure of any diagnostic on any channel activates the Fault indicator, which in turn activates the chassis alarm signal. The module Fault indicator merely reports a channel fault, not a module failure. The module continues to operate properly with as many as two faulty channels. The thermocouple input module supports hot-spare capability which allows online replacement of a faulty module.The thermocouple input module requires a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed to prevent improper installation in a configured chassis. isolated thermocouple input modules. The isolated module allows users to select upscale or downscale burnout detection with the TriStation software. For non-isolated modules, upscale or downscale burnout detection depends on the field termination selected
3706A image is for reference only product style, specific data of manufacture and product version, please refer to the actual product delivery!
3706A 3708E THERMOCOUPLE ANALOG INPUT MODULE SpecificationModel Number | 3706A | 3708E |
Type | TMR | TMR |
Number of input signals | 32 differential, DC coupled | 16 differential, isolated |
Isolated points | No | Yes |
Input update rate | 50 ms, maximum* | 50 ms |
Thermocouple types supported2 | J, K,T | J, K, T, E |
Accuracy/temp range | See Table A | See Table B |
Input resistance (load; | 22 MQ(DC), typical | 30 MQ(DC), minimum |
Noise rejection | ||
Common mode | -85 dB @ 0-60 Hz, minimum -95 dB @ DC, typical | -90 dB @ 0-60 Hz, minimum -l(X) dB @ DC, minimum |
Normal mode | -17dB@60Hz | -3 dB @ 8 Hz, typical -17 dB @ 60 Hz, typical |
Common mode range | ±1() VDC max. (channel-tochannel or channel-to-ground) | ±20() VDC, max (channel-to-channel or channel-to-ground) |
Leg-to-leg isolation | 200 KQ typical | 20 K<2 typical |
Input point protection | 11() VAC, continuous | 11() VAC, continuous |
Reference junction compensation range | 32o-140°F(0°-60oC) | 32°-140°F (0°-60°C) |
Diagnostic indicators | PASS, FAULT, ACTIVE | PASS, FAULT, ACTIVE, CJ FAULT |
Color code | Tan | Deep Yellow |
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for 3706A
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Triconex | 9551-110 | Triconex | 9791-610 | Triconex | 9766-210 | Triconex | 9750-310 |
Triconex | 9651-110 | Triconex | 9561-110 | Triconex | 9795-610 | Triconex | 9783-110 |
Triconex | 9664-110 | Triconex | 9661-710 | Triconex | 9565-710 | Triconex | 9863-710 |
Triconex | 9761-210 | Triconex | 9667-610 | Triconex | 9661-910 | Triconex | 9570-610 |
Triconex | 9787-110 | Triconex | 9763-810 | Triconex | 9750-410 | Triconex | 9662-710 |
Triconex | 9552-610 | Triconex | 9792-610 | Triconex | 9766-510 | Triconex | 9753-110 |
Triconex | 9652-610 | Triconex | 9562-810 | Triconex | 9853-610 | Triconex | 9784-610 |
Triconex | 9664-810 | Triconex | 9661-110 | Triconex | 9566-710 | Triconex | 9571-610 |
Triconex | 9761-410 | Triconex | 9667-710 | Triconex | 9662-110 | Triconex | 9662-810 |
Triconex | 9789-610 | Triconex | 9765-210 | Triconex | 9750-810 | Triconex | 9760-410 |
Triconex | 9553-610 | Triconex | 9793-110 | Triconex | 9771-210 | Triconex | 9785-610 |
Triconex | 9653-610 | Triconex | 9563-810 | Triconex | 9860-610 | Triconex | 9572-610 |
Triconex | 9667-110 | Triconex | 9661-810 | Triconex | 9566-810 | Triconex | 9663-610 |
Triconex | 9762-410 | Triconex | 9667-810 | Triconex | 9662-910 | Triconex | 9760-210 |
Triconex | 9790-610 | Triconex | 9765-610 | Triconex | 9750-210 | Triconex | 9786-110 |
Triconex | 9561-810 | Triconex | 9794-110 | Triconex | 9782-110 | Triconex | 9670-110 |
Triconex | 9661-610 | Triconex | 9565-810 | Triconex | 9861-610 | Triconex | 9670-610 |
Triconex | 9667-910 | Triconex | 9661-510 | Triconex | 9567-810 | Triconex | 9671-610 |
Triconex | 9762-210 | Triconex | 9668-110 | Triconex | 9662-610 | Triconex | 9671-810 |