| Customization: | Available |
|---|---|
| Usage: | PLC MODULE |
| Type: | New and original |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
WOODWARD PLC Module 8400-016 8440-1843 8516-038 PROACT Model II Speed Control Genset Controller Mechanical Turbine Governor TG-13 In Stock
8400-016
8440-1843
8516-038
The Woodward TG-13 (8516-038) is a digital regulator for precise engine speed and load control in harsh industrial environments, featuring robust IP65 protection and multi-protocol communication.
Installation & Debugging Guide
Site: Install in a well-ventilated, vibration-free area, ensuring proper cooling space.
Wiring: Use correct wire sizes, secure connections, and prefer shielded cables for signals.
Setup: Configure basic parameters (e.g., address, communication settings) via the front panel or configuration tool.
Operation & Maintenance Instructions
Interface: Operate via the intuitive LCD menu; password protects critical changes.
Routine Checks: Clean surfaces and check terminals quarterly; inspect internal components annually with power off.
Faults: Use the built-in diagnostic codes and event logs for troubleshooting; contact professionals for complex issues.
Installation of the TG-13 Governor
2. With the spacer and gear in place with the new drive key on the TG-13 drive shaft, tighten the castle nut. The nut should be snug, but need not be torqued. Use the new cotter key to secure the castle nut.
3. Carefully install the new governor-drive assembly where the mechanical governor was removed. No gasket is required on the multi-cylinder mounting surface, although a thin gasket may be used to overcome imperfections in the mounting surface and to assure a good fit. The TG-13 installs with the clockwise output shaft toward the engine. Arrows on the side of the governor identify output-shaft rotation.
Meshing the drive gear with the governor drive on the engine must be done carefully. Pressure must not be exerted while installing the governor. If the gear does not mesh, remove the governor and rotate the drive slightly, then try again. The installation must not require any more pressure than that exerted by the weight of the governor.
4. Tighten the set screw on the one cylinder engine. Evenly torque the four mounting bolts on the multi-cylinder unit.
Operation
Fill the governor with new, clean oil, If possible, use the same weight and grade of oil used in the engine oiler system. The engine oiler oil will work in almost all installations. The only exceptions may be in installations which wilt want to start an extremely cold governor. It is possible in these installations that a lighter (10 weight or 5 weight oil) may have to be used during the cold season. The governor will require about 1.750 quarts of oil. Remove the oil breather screw from the cover and fill through this hole. Add Oil until the oil level is visible in the sight gauge on the side of the governor. Always check the oil level before starting the engine. Add oil if it is not visible in the sight gauge.
Figure 2. TG-13 Governor
Droop Adjustment
Adjustment of droop may be required during TG governor installation if the governor shows instability or is slow in responding to load change.
Instability in the form of hunting or surging indicates possible insufficient droop or insufficient terminal-shaft movement. If the terminal shaft is moving at least 20 degrees between minimum and maximum fuel, it may be necessary to increase droop. Delay in accepting load after a toad change indicates excessive droop.
To change the droop setting: shut down the engine; remove the governor cover, and move the adjusting lever as indicated. Do not move the droop-adjusting lever in the decrease direction too close to the center line of the terminal shaft. Move the lever about 0.8 mm (1/32 of an inch) at a time when adjusting droop. After each move replace the cover and try the operation at the new setting.
Figure 4. Droop-Adjusting Lever Movement 




8516-038 image is for reference only product style, spec ific data of manufacture and product version, please refer to the actual product delivery!
Q: Is your product new or refurbished?
A: All our products are original new with one year warranty.
Q: How many days the goods will arrive my hands if I place the order now?
A: As soon as we receive the payment, I will ship the products immediately.
It usually take 3-5 days from China to your hands.
Q: Could you give me some discount?
A: Contact Stella to get more discount for 8440-1843
Q:Can you ship the goods to my country?
A: Pls don't worry ,We can ship the goods to worldwide
Q:What payment mothod we used?
A:We usually use T/T (Telegraphic Transfer),and we can received with in 1-2days
Q:Can I contact you on Email?
A: You can contact me online to get my email add
Amikon sells automation equipment around the world. With a strong focus on older, obsolete, Automation parts, we pride ourselves in providing high quality parts and services to our customers. Our goal is to provide a seamless purchasing experience that trumps the competition. Low lead time, with quick shipping and processing is our utmost concern. Reducing downtime is extremely important to us and our customers take notice! All orders are prepared by our expertly-skilled team and thoroughly vetted before each shipment.
We are specialized in providing world-reknowed brands: All-en Bradley, A-BB , Bently Nevada, GE ,Honeywell,Emerson, Triconex , Hima ,etc. Even some discontinued ones.We pride ourselves on being a leading provider of industrial automation parts and solutions. Extensive Inventory, Competitive Pricing, Fast Delivery, Global Reach and serves a diverse range of industries with 12 month warranty. Contact us today to learn more about how we can support your business needs.
We have a large inventory of spare parts for industrial control systems. Manufacturers cover a wide range and also work with a wide range of suppliers.Fast shipping to provide you with the best solution to meet your urgent needs If we don't have the stock request quotation you need, You can contact Sales Manager Stella help you.
| Woodward | 8440-1750 | Woodward | 5453-203 | Woodward | 5462-744 |
| Woodward | EASYGEN-1500-55B | Woodward | 5437-672 | Woodward | 9907-164 |
| Woodward | 9905-003 | Woodward | 5464-210 | Woodward | 8271-467 |
| Woodward | SA1509-24 | Woodward | 5466-353 | Woodward | 9905-068 2301A |
| Woodward | EASYGEN-2500-5 | Woodward | 5466-355 | Woodward | 9905-792 |
| Woodward | 9905-463 | Woodward | 5461-655 | Woodward | CMW112 |
| Woodward | 5463-785 | Woodward | 5461-648 | Woodward | 8200-226 |
| Woodward | 5463-473 | Woodward | 5461-644 | Woodward | EASYGEN-1000 |
| Woodward | 5464-414 | Woodward | 5462-718 | Woodward | 8440-1809 |
| Woodward | 5464-544 | Woodward | 9907-029 | Woodward | 9907-028 |
| Woodward | 5463-581 | Woodward | 5462-757 | Woodward | 5438-667 |
| Woodward | 5464-013 | Woodward | 5462-948 | Woodward | 5464-643 |
| Woodward | 5464-211 | Woodward | 5462-408 | Woodward | 5464-648 |
| Woodward | 5417-028 | Woodward | 5500-577 | Woodward | 5464-653 |
| Woodward | 5501-380 | Woodward | 5462-916 | Woodward | 5464-850 |
| Woodward | 5417-175 | Woodward | 5462-758B | Woodward | 5466-026 |
| Woodward | 5417-040 | Woodward | 5461-650 | Woodward | 5466-352 |